aboutsummaryrefslogtreecommitdiffstats
path: root/russian/ircd-hybrid/Makefile
blob: 17df3ace2c86c7a82b8d40eb207c7609003c2817 (plain) (blame)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
# New ports collection makefile for:    ircd-hybrid-ru
# Date Created:             2003.12.14
# Whom:                 Evgueni V. Gavrilov <aquatique@rusunix.org>
#
# $FreeBSD$
#

PORTNAME=   ircd
PORTVERSION=    7.1
PORTREVISION=   3
CATEGORIES= irc russian
MASTER_SITES=   ${MASTER_SITE_SOURCEFORGE} \
        ftp://rusunix.org/pub/FreeBSD/distfiles/
MASTER_SITE_SUBDIR= ircd-hybrid-ru
PKGNAMESUFFIX=  -hybrid-ru
DISTNAME=   ircd-hybrid-ru-7.1rc2

MAINTAINER= aquatique-ports@rambler.ru
COMMENT=    Russian version of well known hybrid IRC server

CONFLICTS=  ircd*

WRKSRC=     ${WRKDIR}/${PORTNAME}${PKGNAMESUFFIX}
USE_OPENSSL=    yes
USE_BISON=  yes
USE_REINPLACE=  yes
GNU_CONFIGURE=  yes
CONFIGURE_ARGS= --sysconfdir=${PREFIX}/etc/ircd-hybrid-ru

MAN8=       ircd.8

.if defined(WITH_SMALL_NET)
CONFIGURE_ARGS+=-enable-small-net
.endif

.if defined(WITH_SYSLOG)
CONFIGURE_ARGS+=--enable-syslog=\"kill squit connect users oper\"
.endif

.if defined(NICKLENGTH)
CONFIGURE_ARGS+=--with-nicklen=${NICKLENGTH}
.endif

.if defined(TOPICLENGTH)
CONFIGURE_ARGS+=--with-topiclen=${TOPICLENGTH}
.endif

.if defined(MAXCONN)
CONFIGURE_ARGS+=--with-maxconn=${MAXCONN}
.endif

pre-extract:
    @${ECHO_MSG} "* * * Build options for ircd-hybrid-ru * * *"
    @${ECHO_MSG} "Issue make WITH_SMALL_NET=yes to build server optimized for small network"
    @${ECHO_MSG} "Issue make WITH_SYSLOG=yes to enable logging via syslogd"
    @${ECHO_MSG} "You can define maximum nick length. For example make NICKLENGTH=46 (default is 30)"
    @${ECHO_MSG} "You can define maximum topic length. For example make TOPICLENGTH=254 (default is 120; maximum is 390)"
    @${ECHO_MSG} "You can define maximum number of connections for ircd. For example make MAXCONN=512"

pre-install:
    @${SH} ${PKGINSTALL} ${PKGNAME} PRE-INSTALL
    @${REINPLACE_CMD} -e 's,ircd/etc/codepage,etc/ircd-hybrid-ru/codepage,' ${WRKSRC}/etc/example.conf
    @${REINPLACE_CMD} -e 's,/ircd/modules,/lib/ircd-hybrid-ru-modules,' ${WRKSRC}/etc/example.conf

post-install:
    @${INSTALL_SCRIPT} -m 555 ${FILESDIR}/ircd-hybrid-ru.sh.sample ${PREFIX}/etc/rc.d
    @${CHOWN} -R ircdru:ircdru ${PREFIX}/etc/ircd-hybrid-ru
    @${CHOWN} -R ircdru:ircdru /var/log/ircd-hybrid-ru
    @${MKDIR} ${DOCSDIR}
    @${INSTALL_DATA} ${WRKSRC}/RELNOTE* ${DOCSDIR}
    @${INSTALL_DATA} ${WRKSRC}/doc/*.txt ${DOCSDIR}
    @${INSTALL_DATA} ${WRKSRC}/doc/server-version-info ${DOCSDIR}
    @${CAT} ${PKGMESSAGE}

.include <bsd.port.mk>